NH3 3E 1000 Tecnosens
new
- Manufacturer: Tecnosens
Amperometric 3 electrode sensor cell Measuring Range: 0-1000ppm Sensitivity Range: 6 nA/ppm ± 3 nA/ppm Zero Current at 20°C: <± 40 nA Resolution at 20°C: <15 ppm Bias Potential: 0 mV Linearity: <5% full scale Res...
Brescia, ItalyH2 3E 1% Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-10000ppm Sensitivity Range: 10 nA/ppm ± 5 nA/ppm Zero Current at 20°C: < ± 250 nA Resolution at 20°C: < 20 ppm Bias Potential: 0 V Linearity: < 5% full scale Response Time at 20°C: t50 < 40 s c...
Brescia, ItalyCOCl2 3E 1 Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-1 ppm Sensitivity Range: 650 nA/ppm ± 150 nA/ppm Zero Current at 20°C: < ± 10 nA Resolution at 20°C: < 0.02 ppm Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20°C: t50 < 60 ...
Brescia, ItalyAQ7SO2 Tecnosens
new
- Manufacturer: Tecnosens
City Technology - Electrochemical Cell for Sulfur Dioxide Air quality cell
Brescia, ItalyAQ3ND Tecnosens
new
- Manufacturer: Tecnosens
City Technology - Electrochemical Cell for Nitrogen Dioxide Air Quality Cell
Brescia, ItalyA3OZ Tecnosens
new
- Manufacturer: Tecnosens
Nominal Range: 0-10ppm Maximum Overload: 100ppm Expected Operating Life: Two years Output Signal: 2.2 ± 0.5 μA/ppm Resolution at 20°C: 20ppb Temperature Range: -20°C to +50°C Pressure Range: Atmospheric ± 10% Pre...
Brescia, Italy7HYT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-1000 ppm Sensitivity Range: 0.03 ± 0.01 μA/ppm Baseline Offset at 20°C: 0 to -25 ppm H2 equivalent Bias Potential: not required Linearity: linear Response Time: < 85 seconds (t90) Long Term Sen...
Brescia, Italy7HL Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-50 ppm HCl Maximum overload: 100 ppm HCl Filter: None Sensitivity: 0.75 ± 0.25 μA/ppm Response Time (T90): <120 Seconds at 20°C Ze...
Brescia, Italy7HH Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-50 ppm H2S Maximum Overload: 500 ppm H2S Filter: None Sensitivity: 1.7 ± 0.3 μA/ppm Response Time (T90): <30 Seconds at 20°C Basel...
Brescia, Italy7HHLM Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-50 ppm H2S Maximum overload: 500 ppm H2S Filter: None Sensitivity: 1.7 ± 0.3 μA/ppm Response Time (T90): <30 Seconds at 20°C Zero ...
Brescia, Italy7HCN Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0 - 100 ppm HCN Filter: None Sensitivity: 0.10 ± 0.02 μA/ppm Response Time (T90): <200 Seconds at 20°C Resolution (Electronics depen...
Brescia, ItalyD-400-3V Tecnosens
new
- Manufacturer: Tecnosens
D-400-3V is the world's smallest dual beam CO2 module. Due to its excellent stability and resistance to temperature variations, it is particularly suitable for uses in factories, greenhouses, hospitals, and more ...
Brescia, ItalyD-300 Tecnosens
new
- Manufacturer: Tecnosens
NDIR dual beam module for CO2 measurement. Its stability and ability to compensate for temperature variations make it particularly useful for storage environments, greenhouses, hospitals, etc. Accuracy ± 300ppm ±...
Brescia, Italy5SFF Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Nominal Range: 0-2000 ppm SO2 Maximum Overload: 5000 ppm SO2 Filter: To remove effects of H2S and HCl Filter Life: >200,000 ppm hours (1000 ppm H2S @ 5...
Brescia, Italy5SF Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-2000 ppm SO2 Maximum Overload: 5000 ppm SO2 Filter: None Sensitivity: 0.10 ± 0.02 μA/ppm Resolution: 1 ppm Response Time (T90): <3...
Brescia, Italy