 - HCN 3E 30 F Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0 - 30 ppm Sensitivity Range: 60 nA/ ppm ± 15 nA/ ppm Zero Current at 20°C: < ± 15 nA Resolution at 20°C: < 0.2 ppm Bias Potential: 0mV Linearity: < 5% full scale Response Time at 20°C: t50 < 25 ... Brescia, Italy
 - HCN 2E 30 F Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0 - 30 ppm Sensitivity Range: 30 nA/ ppm ± 15 nA/ ppm Zero Current at 20°C: < ± 5 nA Resolution at 20°C: < 0.2 ppm Bias Potential: not required Linearity: < 5% full scale Response Time at 20°C t5... Brescia, Italy
 - F2 3E 1 Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-1 ppm Sensitivity Range: 100 nA/ppm ± 300 nA/ppm (negative current) Zero Current at 20°C: < ± 20 nA Resolution at 20°C: < 0.02 ppm Bias Potential: 0 mV Linearity: < 5% full scale Response Time ... Brescia, Italy
 - B2H6 3E 1 LT Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-1ppm Sensitivity Range: 2200 ± 500 nA/ppm Baseline Offset at 20°C: < ± 20 nA Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20°C: < 30 seconds (t90) Long Term Sensitivity Dri... Brescia, Italy
 - A3STF Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 4-electrode electrochemical Measurement Range: 0-10ppm SO2 Maximum Overload: 100 ppm Filter: To remove H2S and HCl Sensitivity: 0.60 ± 0.12 μA/ppm Response Time (T90): < 40 second... Brescia, Italy
- A3CO Tecnosens- Manufacturer: Tecnosens
 - Nominal Range: 0-500ppm Maximum Overload: 1000ppm Expected Operating Life: Two years Output Signal: 0.2 ± 0.04 μA/ppm Resolution: 100ppb Temperature Range: -20°C to +50°C Pressure Range: Atmospheric ± 10% Pressur... Brescia, Italy
 - 7NDH Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-20 ppm Sensitivity Range: 1.40 ± 0.30 μA/ppm Baseline Offset at 20°C: -0.1 to +0.1 ppm NO2 equivalent Bias Potential: not required Linearity: linear Response Time: < 40 seconds (t90) Long Term ... Brescia, Italy
 - 7ETO Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-20 ppm C2H4O Maximum Overload: 100 ppm C2H4O Filter: None Sensitivity: 2.25 ± 0.65 μA/ppm Response Time (T90): <140 Seconds Baseli... Brescia, Italy
 - 7EF Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-10000 ppm CO Maximum Overload: 2000 ppm CO Filter: To remove SOx/NOx and H2S Sensitivity: 0.10 ± 0.02 μA/ppm Response Time (T90) 7... Brescia, Italy
 - CDM7162-C00 Tecnosens- Manufacturer: Tecnosens
 - The CDM7162 is a dual beam NDIR module developed for air quality control systems, ventilation systems, air conditioning systems, etc. The module comes calibrated and with I2C and UART interfaces. From a size pers... Brescia, Italy
 - CD-200 Tecnosens- Manufacturer: Tecnosens
 - The CD-200 product series offers NDIR modules for CO2 with current- or voltage-selectable output transmitters: field-selectable settings by the customer. Measurement Ranges: 0-2000 ppm, 0-5000 ppm and 0-10000 ppm... Brescia, Italy
 - S+4 2ECOH Tecnosens- Manufacturer: Tecnosens
 - Electrochemical cell for carbon monoxide, with high sensitivity to hydrogen. Measurement Range 0 - 200 ppm Output Signal 175 ± 50 nA / ppm Linearity: within ± 5% Repeatability <± 5% Response time, T90 <30 s Maxim... Brescia, Italy
 - GS+7NO Tecnosens- Manufacturer: Tecnosens
 - Measurement Range 0 - 100 ppm Output Signal 550 ± 150 nA / ppm Linearity: Linear Repeatability < ±2% NO2 equivalent Response time, T90 <30 s Maximum Overload 1500 ppm Long-term Output Drift <20% per annum Recomme... Brescia, Italy
 - 4PH Fast Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-5 ppm Sensitivity Range: 1.7 μA/ppm ± 0.3 μA/ppm Baseline Offset at 20°C: -0.05 to +0.2 ppm equivalent Bias Potential: Not required Linearity: Linear Response Time at 20°C: < 60 seconds (t90) L... Brescia, Italy
- 3STF Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-100 ppm CO Maximum Overload: 500 ppm CO Filter: To remove H2S Sensitivity: 0.37 ± 0.07 μA/ppm Resolution: 0.5 ppm (electronics dep... Brescia, Italy