 - O3 3E 1 F Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-1 ppm Sensitivity Range: 450 +/- 150 nA/ppm (negative signal) Zero Current at 20°C: < ± 10 nA Resolution at 20°C: < 0.03 ppm Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20... Brescia, Italy
 - H-250-5V Tecnosens- Manufacturer: Tecnosens
 - The H-250 series consists of the most compact NDIR modules for measuring high CO2 concentrations on the market. Due to its stability, built-in temperature change compensation as well as easy handling of the modul... Brescia, Italy
- NH3 3E 5000 SE Tecnosens- Manufacturer: Tecnosens
 - Amperometric 3 electrode sensor cell Measuring Range: 0-5000ppm Sensitivity Range: 4 nA/ppm ± 2 nA/ppm Zero Current at 20°C: <± 100 nA, typically 40 nA Resolution at 20°C <50 ppm, typically 20 ppm Bias Potential:... Brescia, Italy
- NH3 3E 1000 SE Tecnosens- Manufacturer: Tecnosens
 - Amperometric 3 electrode sensor cell Measuring Range: 0-1000ppm Sensitivity Range: 8 nA/ppm ± 4 nA/ppm Zero Current at 20°C: <± 40 nA Resolution at 20°C: <12 ppm Bias Potential: 0 mV Linearity: <5% full scale Res... Brescia, Italy
- NH3 3E 1000 Tecnosens- Manufacturer: Tecnosens
 - Amperometric 3 electrode sensor cell Measuring Range: 0-1000ppm Sensitivity Range: 6 nA/ppm ± 3 nA/ppm Zero Current at 20°C: <± 40 nA Resolution at 20°C: <15 ppm Bias Potential: 0 mV Linearity: <5% full scale Res... Brescia, Italy
 - H2 3E 1% Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-10000ppm Sensitivity Range: 10 nA/ppm ± 5 nA/ppm Zero Current at 20°C: < ± 250 nA Resolution at 20°C: < 20 ppm Bias Potential: 0 V Linearity: < 5% full scale Response Time at 20°C: t50 < 40 s c... Brescia, Italy
 - COCl2 3E 1 Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-1 ppm Sensitivity Range: 650 nA/ppm ± 150 nA/ppm Zero Current at 20°C: < ± 10 nA Resolution at 20°C: < 0.02 ppm Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20°C: t50 < 60 ... Brescia, Italy
 - AQ7SO2 Tecnosens- Manufacturer: Tecnosens
 - City Technology - Electrochemical Cell for Sulfur Dioxide Air quality cell Brescia, Italy
 - AQ3ND Tecnosens- Manufacturer: Tecnosens
 - City Technology - Electrochemical Cell for Nitrogen Dioxide Air Quality Cell Brescia, Italy
- A3OZ Tecnosens- Manufacturer: Tecnosens
 - Nominal Range: 0-10ppm Maximum Overload: 100ppm Expected Operating Life: Two years Output Signal: 2.2 ± 0.5 μA/ppm Resolution at 20°C: 20ppb Temperature Range: -20°C to +50°C Pressure Range: Atmospheric ± 10% Pre... Brescia, Italy
 - 7HYT Tecnosens- Manufacturer: Tecnosens
 - Measuring Range: 0-1000 ppm Sensitivity Range: 0.03 ± 0.01 μA/ppm Baseline Offset at 20°C: 0 to -25 ppm H2 equivalent Bias Potential: not required Linearity: linear Response Time: < 85 seconds (t90) Long Term Sen... Brescia, Italy
 - 7HL Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-50 ppm HCl Maximum overload: 100 ppm HCl Filter: None Sensitivity: 0.75 ± 0.25 μA/ppm Response Time (T90): <120 Seconds at 20°C Ze... Brescia, Italy
 - 7HH Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-50 ppm H2S Maximum Overload: 500 ppm H2S Filter: None Sensitivity: 1.7 ± 0.3 μA/ppm Response Time (T90): <30 Seconds at 20°C Basel... Brescia, Italy
 - 7HHLM Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-50 ppm H2S Maximum overload: 500 ppm H2S Filter: None Sensitivity: 1.7 ± 0.3 μA/ppm Response Time (T90): <30 Seconds at 20°C Zero ... Brescia, Italy
 - 7HCN Tecnosens- Manufacturer: Tecnosens
 - MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0 - 100 ppm HCN Filter: None Sensitivity: 0.10 ± 0.02 μA/ppm Response Time (T90): <200 Seconds at 20°C Resolution (Electronics depen... Brescia, Italy