GS+7CL2 Tecnosens
- Manufacturer: Tecnosens
Measurement Range 0 - 20 ppm Output Signal 1000 ± 300 nA / ppm Linearity: Linear Repeatability < ±2% Cl2 equivalent Response time, T90 <60 s Maximum Overload 250 ppm Long-term Output Drift <20% per annum Recommen...
Brescia, Italy
GS+4NH3-300 Tecnosens
- Manufacturer: Tecnosens
Range 0 - 300 ppm Typical Baseline Range (pure air) ±2 ppm NH3 equivalent Output Signal 40 ± 15 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 500 ppm Long-term Output Drift <20% per annum Reco...
Brescia, Italy
3NT Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0-100 ppm Sensitivity Range: 0.55 ± 0.11 μA/ppm Baseline Offset at 20°C: 0 to 3 ppm equivalent Bias Potential: +300 mV Linearity: linear Response Time at 20°C: < 10 seconds (t90) Long Term Sensit...
Brescia, Italy
3HYT Tecnosens
- Manufacturer: Tecnosens
Measuring Range: 0-1000ppm Sensitivity Range: 30 ± 10 nA/ppm Baseline Offset at 20°C: 0 to 15 ppm equivalent Bias Potential: Not required Linearity: Linear Response Time at 20°C: < 50 seconds (t90) Long Term Sens...
Brescia, ItalyFCX-MW-F Tecnosens
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-95% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, ItalyFCX-MEP2-F Tecnosens
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-25% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, Italy
GS+4NH3-100 Tecnosens
- Manufacturer: Tecnosens
Range 0 - 100 ppm Typical Baseline Range (pure air) ±1 ppm NH3 equivalent Output Signal 100 ± 30 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 200 ppm Long-term Output Drift <20% per annum Rec...
Brescia, ItalyGS+4ETO Tecnosens
- Manufacturer: Tecnosens
Measurement Range 0 - 20 ppm Output Signal 1900 ± 600 nA / ppm Linearity: Linear Repeatability < ±2% ETO equivalent Response time, T90 <120 s Maximum Overload 100 ppm Long-term Output Drift <20% per annum Recomme...
Brescia, ItalyGS+4CO Tecnosens
- Manufacturer: Tecnosens
Electrochemical carbon monoxide cell with range 0-2000 ppm, manufactured by DD Scientific Suitable for industrial applications, especially for portable detectors. Range 0 - 2000 ppm Output Signal 70 ± 20nA/ppm Li...
Brescia, Italy
2EF Tecnosens
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 2-electrode electrochemical Measurement Range: 0-200 ppm CO Maximum Overload: 500 ppm CO Filter: To remove SO2 and H2S Sensitivity: 0.10 ± 0.02 μA/ppm Resolution: 1 ppm Response T...
Brescia, Italy
Infra.Sens AK5 Tecnosens
- Manufacturer: Tecnosens
The Infra.Sens line is designed par high quality NDIR analysis. In the design phase, special attention was paid to high stability and Low Detection Limit. Through the use of high-performance IR-LEDs and micro the...
Brescia, Italy
ULTRA.sens® AK100 TBH (UVRAS) Tecnosens
- Manufacturer: Tecnosens
The Ultrasens line is the first OEM gas measurement module based on miniaturized UV LEDs. The stability and service life of these UV LEDs allows for extremely accurate gas analysis below the PPB range. Using 2 LE...
Brescia, Italy
ULTRA.sens® AK100 TBH Tecnosens
- Manufacturer: Tecnosens
The Ultrasens line is the first OEM gas measurement module based on miniaturized UV LEDs. The stability and service life of these UV LEDs allows for extremely accurate gas analysis below the PPB range. Using 2 LE...
Brescia, Italy
Ultra.Sens AK550 Tecnosens
- Manufacturer: Tecnosens
The Ultrasens line is the first OEM gas measurement module based on miniaturized UV LEDs. The stability and service life of these UV LEDs allows for extremely accurate gas analysis below the PPB range. Using 2 LE...
Brescia, Italy
Ultra.Sens AK25 Tecnosens
- Manufacturer: Tecnosens
The Ultrasens line is the first OEM gas measurement module based on miniaturized UV LEDs. The stability and service life of these UV LEDs allows for extremely accurate gas analysis below the PPB range. By using 2...