EXCHANGERS 112292
Used 437 Sq. Ft. Horizontal Utube Heat Exchanger. Mfg. by Fabsco Shell and Tube LLC in 2012. All 304L Stainless Steel. 18"/24" diameter x 16'0" F/F. Previous Service: AGR Rich Flash Gas Cooler.
Cleveland, TX- Cleveland, TX
EXCHANGERS 105821
- Manufacturer: DAEKYUNG
UNUSED SHELL AND TUBE HEAT EXCHANGER; MFG. BY DAEKYUNG IN 2008;
Cleveland, TXEXCHANGERS 114775
Unused 2685 sq. ft. vertical heat exchanger. 7.5 Design duty (MMBTU/Hr). Mfg. by Alliance Fab (Graham) in 2022. Shell: 150 psi @ 212 deg. F. Tubes: 50FV psi @ 400 deg. F. 34" x 156". Primary Surface Condenser. ...
Cleveland, TXEXCHANGERS 114776
Unused 96 sq. ft. vertical heat exchanger. 0.4 Design duty (MMBTU/Hr). Mfg. by Alliance Fab (Graham) in 2022. Shell: 150 psi @ 212 deg. F. Tubes: 50FV psi @ 400 deg. F. 10" x 72". Secondary Surface Condenser. U...
Cleveland, TXEXCHANGERS 113767
Used 664 sq. ft. Exchanger. Mfg. by Aztech Heat Exchanger in 2014. Shell: Carbon Steel, 124 psi @ 122 deg. F. Tubes: Stainless Steel, 116 psi @ 212 deg. F.
Cleveland, TXEXCHANGERS 113157
Used approximately 150 sq. ft. Southern heat exchanger. Approximately 12" diameter X 6' long shell. 3/4" stainless steel tubes. Shell side 50 FV @ 250 degrees F. Tube side 50 psi @ 250 degrees F. Horizontal...
Cleveland, TXEXCHANGERS 107242
- Manufacturer: SUPERCHANGER
FINISHED PRODUCT HEAT EXCHANGER; MFG. BY SUPERCHANGER IN 1998; MODEL #UX-296-HP-45;;
Cleveland, TXEXCHANGERS 114771
Unused 650 sq. ft. vertical heat exchanger. Mfg. by Wuxi Zhicherq Biochemical Eng. in 2021. 1.8 Design duty (MMBTU/Hr). Shell Design Rating: 147/FV psig @ 428 deg. F. Tube Design Rating: 174/FV psig @ 428 deg. ...
Cleveland, TXEXCHANGERS 112942
Used 18,294 Sq. Ft. vertical Plate Exchanger. Mfg. by APV in 2012. With (2)20" inlets & (2)20" outlets. Model #S280M14 Paraflow. Previous Service: GI Closed Loop CW heat Exchanger 2;
Cleveland, TXEXCHANGERS 112941
Used 18,294 Sq. Ft. vertical Plate Exchanger. Mfg. by APV in 2012. With (2)20" inlets & (2)20" outlets. Model #S280M14 Paraflow. Previous Service: GI Closed Loop CW heat Exchanger 1;
Cleveland, TXEXCHANGERS 114763
Unused 1,021 sq. ft. vertical Plate and Frame heat exchanger. 8.7 Design duty (MMBTU/Hr). Mfg. by APV (SPX Flow) in 2023. Shell: 150 psi @ 320 deg. F. Tubes: 150 psi @ 320 deg. F.; Model #L039M-10. Treated Feed...
Cleveland, TXEXCHANGERS 114773
Unused 1021 sq. ft. vertical Plate and Frame heat exchanger. 8.7 Design duty (MMBTU/Hr). Mfg. by APV (SPX Flow) in 2023. Model #L039M-10. Shell: 150 psi @ 320 deg. F. Tubes: 150 psi @ 320 deg. F.; Treated Feed R...
Cleveland, TXEXCHANGERS 113511
Used 2633 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 32" diameter x 20'0" F/F. Shell: Carbon Steel, 75FV psi @ 300 deg. F. Tubes: 316L Stainless Steel, (503) 1" O.D. x 16 BWG, 75FV ...
Cleveland, TXEXCHANGERS 113515
Used 930 Sq. Ft. Vertical Heat Exchanger. Mfg. by Southern Heat Exchanger in 1989. 18" diameter x 20'0" F/F. Shell: Carbon Steel, 75FV psi @ 250 deg. F. Tubes: 316L Stainless Steel, (237) .75" O.D. x 16 BWG, 75FV...
Cleveland, TX