Building Filters
EXCHANGERS 114558
Used 250 sq. ft. horizontal exchanger. 24" diameter x 6'0" F/F. Shell, tubes and heads stainless steel.
Cleveland, TXEXCHANGERS 114731
Unused 1795 sq. ft. horizontal heat exchanger. 14.66 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. . Shell Design Rating: 135/FV psig @ 320 deg. F. Tube Design Rating: 170/FV psig @ 30...
Cleveland, TXEXCHANGERS 114709
Unused 103 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 1.3 Design duty (MMBTU/Hr). Shell Design Rating : 220/FV psig @ 430/300 deg. F. Tube Design Rating: 232/FV psig @ 430/400 d...
Cleveland, TXEXCHANGERS 114766
Unused 96 sq. ft. vertical heat exchanger. 0.4 Design duty (MMBTU/Hr). Alliance Fab (Graham) in 2022. Shell: 150 psi @ 212 deg. F. Tubes: 150FV psi @ 400 deg. F.; 10" x 72". Secondary Surface Condenser. Under N...
Cleveland, TXEXCHANGERS 113072
Unused 3620 sq. ft. Graphite heat exchanger. Mfg. by SGL Carbon. Model RS77-3-475.15.1.V-HF1-HF1-FRP-8D. The heads are Mfg. by An-Cor Industrial Plastics. Shell only is coded. Originally designed as a Primary We...
Cleveland, TXEXCHANGERS 114727
Unused 521 sq. ft. heat exchanger. Mfg. by Fabsco Shell and Tube in 2023. 1.75 Design duty (MMBTU/Hr). Shell: 270FV psi @ 300 deg. F. Tubes: 210 psi @ 150 deg. F. 21.25" X 120". LP Lean Amine Cooler. Under Nitro...
Cleveland, TXEXCHANGERS 114764
Unused 108 sq. ft. vertical heat exchanger. 4.5 Design duty (MMBTU/Hr). Mfg. by Wuxi Chemical Equipment (China) in 2023. Shell: 174 psi @ 428 deg. F. Tubes: 174 psi @ 428 deg. F.; 10" x 10'0". Hot Water Tank H...
Cleveland, TXEXCHANGERS 114248
Previously Utilized in an API Facility. Used Condenser for K-2407 / R-2408; 340 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 114247
Previously Utilized in an API Facility. Used Condenser for K-2405 / R-2406; 92 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 114245
Used Condenser for K-2405 / R-2406; 92 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel shell, tubes and heads. 90 psi @ 390 deg. F rated shell and tubes.
Cleveland, TXEXCHANGERS 114549
Used 225 sq. ft. vertical exchanger. Mfg. by Perry Products in 2015. 12" diameter x 11'0" F/F. Shell, tubes and heads all 304L stainless steel. 100 psi @ 320 deg. F. shell. 75FV psi @ 320 deg. F. tubes. (104) 3/4...
Cleveland, TXEXCHANGERS 113761
Used 1448 sq. ft. double diameter horizontal exchanger. Mfg. by Perry Products in 1999. 26"/36" diameter x 18'0" F/F. Shell: 304LSS 100 psi @ 350 deg. F. Tubes: 304LSS 100 psi @ 350 deg. F. (444)-3/4" O.D. x 18 BWG.
Cleveland, TXEXCHANGERS 113776
Used 375 sq. ft. Exchanger. Mfg. by Gaspar in 2005. 14" diameter x 20'0" F/F. Shell: Carbon Steel, FV/123 psi @ 350 deg. F. Tubes: Hastelloy C 276, FV/123 psi @ 350 deg. F. (96) 3/4" O.D. x .065".
Cleveland, TXEXCHANGERS 113508
Used 1004 Sq. Ft. Vertical Heat Exchanger. Mfg. by Metler in 2012. 28" diameter x 7'0" F/F. Shell: Carbon Steel, 150 psi @ 302 deg. F. Tubes: Stainless Steel, (731) 3/4" O.D. x 16 BWG, 116FV @ 302 deg. F. Heads: ...
Cleveland, TXEXCHANGERS 114124
Used 832 Sq Ft Vertical Shell and Tube heat exchanger. Manufactured by Rubicon in 1998. Carbon Steel Shell rated 200 PSI @ 450 deg. F. Hastelloy C276 Tubes rated 50 PSI/FV @ 350 deg. F. 222-1"OD x 16 BWG tubes 14...
Cleveland, TX