D-300-3V Tecnosens
new
- Manufacturer: Tecnosens
NDIR dual beam module for CO2 measurement. Its stability and ability to compensate for temperature variations make it particularly useful for storage environments, greenhouses, hospitals, etc. Accuracy ± 300ppm ±...
Brescia, ItalyCMM5042 Tecnosens
new
- Manufacturer: Tecnosens
The CMM5042 carbon monoxide module is Figaro's new module using the TGS5042 sensor, widely used for residential and commercial CO detectors with excellent durability and stability over time. This module provides ...
Brescia, Italy7E Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-1000 ppm CO Maximum Overload: 2000 ppm CO Filter: To remove SOx/NOx and H2S Sensitivity: 0.10 ± 0.02 μA/ppm Response Time (T90): <...
Brescia, ItalyCD-300 Tecnosens
new
- Manufacturer: Tecnosens
The CD-300 product series offers NDIR modules for CO2 with current- or voltage-selectable output transmitters: field-selectable settings by the customer via jamper. Measurement Ranges: 0-2000 ppm, 0-3000 ppm, 0-5...
Brescia, ItalyS+4 2ECO Tecnosens
new
- Manufacturer: Tecnosens
Electrochemical carbon monoxide cell for air quality applications, home CO detectors, ventilation, and underground parking lots. Measurement Range 0 - 1000 ppm Output Signal 50 ± 20 nA / ppm Linearity Within ±5% ...
Brescia, Italy3SF Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-2000 ppm CO Maximum Overload: 5000 ppm CO Filter: None Sensitivity: 0.10 ± 0.02 μA/ppm Resolution: 1 ppm (electronics dependant) R...
Brescia, ItalyGS+7NH3-1000 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 1000 ppm Typical Baseline Range (pure air) ±10 ppm NH3 equivalent Output Signal 8 ± 4 nA/ppm Linearity Linear Response Time, T90 <60 s Maximum Overload 1500 ppm Long-term Output Drift <20% per annum Rec...
Brescia, ItalyGS+7H2S Tecnosens
new
- Manufacturer: Tecnosens
Typical Baseline Range: <±1 ppm H2S equivalent Measurement Range: 0 - 200 ppm Output Signal: 370 ± 100 nA / ppm Linearity: Linear Repeatability: < ±1% H2S equivalent Response Time, T90: <40 s Maximum Overload: 10...
Brescia, ItalyGS+7CL2 Tecnosens
new
- Manufacturer: Tecnosens
Measurement Range 0 - 20 ppm Output Signal 1000 ± 300 nA / ppm Linearity: Linear Repeatability < ±2% Cl2 equivalent Response time, T90 <60 s Maximum Overload 250 ppm Long-term Output Drift <20% per annum Recommen...
Brescia, ItalyGS+4NH3-300 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 300 ppm Typical Baseline Range (pure air) ±2 ppm NH3 equivalent Output Signal 40 ± 15 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 500 ppm Long-term Output Drift <20% per annum Reco...
Brescia, Italy3NT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-100 ppm Sensitivity Range: 0.55 ± 0.11 μA/ppm Baseline Offset at 20°C: 0 to 3 ppm equivalent Bias Potential: +300 mV Linearity: linear Response Time at 20°C: < 10 seconds (t90) Long Term Sensit...
Brescia, Italy3HYT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-1000ppm Sensitivity Range: 30 ± 10 nA/ppm Baseline Offset at 20°C: 0 to 15 ppm equivalent Bias Potential: Not required Linearity: Linear Response Time at 20°C: < 50 seconds (t90) Long Term Sens...
Brescia, ItalyFCX-MW-F Tecnosens
new
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-95% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, ItalyFCX-MEP2-F Tecnosens
new
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-25% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, ItalyGS+4NH3-100 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 100 ppm Typical Baseline Range (pure air) ±1 ppm NH3 equivalent Output Signal 100 ± 30 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 200 ppm Long-term Output Drift <20% per annum Rec...
Brescia, Italy