EXCHANGERS 114552
Used 575 sq. ft. vertical exchanger. Mfg. by Louisville Exchanger and Vessel in 2021. 16" diameter x 16'0" F/F. Shell, tubes and heads all 304 stainless steel. 75FV psi @ 250 deg. F. shell. 75FV psi @ 360 deg. F....
Cleveland, TX
EXCHANGERS 112345
Used 110 sq. ft. horizontal exchanger. Mfg. by Energy Exchanger Company in 2012. 26" diameter x 10'0" F/F. Carbon Steel. Shell 242 psi @ 145 deg. F. Tubes 650 psi @ 265 deg. F. (534) 3/4" x .083". Previous Servic...
Cleveland, TX
EXCHANGERS 114743
Unused 3181 sq. ft. Horizontal heat exchanger. 10.18 Design duty (MMBTU/Hr). Mfg. by Fabsco Shell and Tube in 2023. Shell Design Rating: 295/FV psi @ 310 deg. F. Tube Design Rating: 230 psi @ 150 deg. F. Shell m...
Cleveland, TX
EXCHANGERS 114742
Unused 284 sq. ft. Horizontal heat exchanger. Mfg by Fabsco Shell and Tube in 2023.. 2.32 Design duty (MMBTU/Hr). Shell Design Rating: 95/FV psi @ 300 deg. F. Tube Design Rating: 120 psi @ 150 deg. F. Shell mawp ...
Cleveland, TX
EXCHANGERS 113207
Used 75 Estimated Sq. Ft. 304L Stainless Steel Vertical Plate Heat Exchanger. Mfg. by APV in 2015. With Carbon Steel Frame and 304L Stainless Steel Plates. Model #M-10. Rated mawp FV/150 psi @ 329 deg. F. mdmt -...
Cleveland, TX
EXCHANGERS 113125
Used 235 sq. ft. Exchanger. Mfg. by JD Cousins in 2003. Previous Service: 18" Evaporator.
Cleveland, TX
Cleveland, TX
EXCHANGERS 114713
Unused 569 sq. ft. horizontal heat exchanger. Mfg. by Wuxi Chemical Equipment in 2023. 1.625 Design duty (MMBTU/Hr). Shell Design Rating: 200/FV psig @ 300 deg. F. Tube Design Rating: 155 psig @ 300 deg. F. She...
Cleveland, TX
EXCHANGERS 112852
Used 3007 sq. ft. U-Tube exchanger. Mfg. by Energy Exchanger Company. Previous Service: Makeup Water Trim Heater.
Cleveland, TX
EXCHANGERS 112851
Used 1640 sq. ft. U-Tube exchanger. Mfg. by Energy Exchanger Company in 2011. Previous Service: Wastewater Cooler.
Cleveland, TX
EXCHANGERS 95274
- Manufacturer: ALFA-LAVAL
MCB/CTW EXCHANGER; MFG. BY ALFA-LAVAL IN 1995; MODEL #AM20-WFC; CS FRAME; 316SS PLATES;
Cleveland, TX
EXCHANGERS 114729
Unused 168 sq. ft. horizontal heat exchanger. 0.443 Design duty (MMBTU/Hr). Mfg. by The Anup Eng. (India) in 2022. . Shell Desing Rating: 105/FV psig @ 300/300 deg. F. Tube Design Rating: 120/FV psig @ 150/300 d...
Cleveland, TX
EXCHANGERS 99557
KELLOGG #136-C; PREVIOUS SERVICE - SYN GAS METHANATOR FEED EXCHANGER; SHELL & BUNDLE REPLACED BY TEXAS METAL FAB IN 1981;
Cleveland, TX
EXCHANGERS 114554
Used 459 sq. ft. vertical exchanger. Mfg. by Perry Products in 2015. 18" diameter x 10'0" F/F. Tubes and heads stainless steel. With expansion joint.
Cleveland, TX
EXCHANGERS 114553
Used 650 sq. ft. vertical exchanger. Mfg. by Doyle & Roth in 1993. 24" diameter x 10'0" F/F. Shell, Tubes and heads stainless steel. With expansion joint.
Cleveland, TX