- Trusted Seller
MAN sewage gas/natural gas generator (CHP) MAN E 2876 LE - 150 KW
- Manufacturer: MAN
- Model: LE
- Hours: 69.106
- Power: 150
MAN Sewage Gas/Natural Gas Generator (CHP) MAN E 2876 LE Sewage gas/natural gas power and heat generator from 2012 with 69,106 operating hours, with control unit, AC generator defective. 1 available 150 kWel x 1...
- Trusted Seller
MAN emergency power diesel D2565 ME - 92 KW / 100 KVA
- Manufacturer: MAN
- Hours: 402
- Power: 92
MAN Diesel (Emergency Power) D2565 ME Diesel generator from 1977 with 402 operating hours, with silencer and cooling but without control unit and day tank. 1 available 80 kWel x 1,500 rpm, 400 V/50 Hz. AC Genera...
- Trusted Seller
Sokratherm gas CHP GG 110iSI – MAN E2866 E301 - 110 KWel
- Manufacturer: MAN
- Hours: 21019
- Power: 110
Sokratherm Gas CHP GG 110iSI – MAN E2866 E301 Gas-fired power and heat generator from 1998, with 21,019 operating hours, with control system. 1 available 110 kWel x 1,500 rpm, 400 V/50 Hz. AC generator: Marelli ...
2011 MAN 25.284 6X2/4 HPC 50 N
- Manufacturer: MAN
- Hours: 87021 h
CHP compact module (heat exchanger module) soundproofed with electric cabinet Engine: MAN; type E0834 E302; Gas-Otto 4-stroke engine, 1500 rpm; power mech. 54kW, ignition control unit Motortech MIC 500 (MIC 520) ...
Leipzig, Germany2008 CHP / CHP MAN
- Manufacturer: MAN
- Hours: 1000 h
- Power: 600kW
For sale The current operating hour is the aggregate (1000h). The unit is complete with control cabinet, silencer and documents.
Cologne, Germany1990 CHP / CHP MAN
- Manufacturer: MAN
- Model: D2866
- Hours: 3620 h
- Power: 253 kW
For sale. The current operating hour level for the unit is (705h). The unit is complete with control cabinet, silencer and documents.
Cologne, Germany2004 CHP / CHP MAN
- Manufacturer: MAN
- Hours: 36,000 h
- Power: 119 KW
For sale a CHP / CHP is offered. The current operating hour is the aggregate (36,000 h). The unit is complete with control cabinet, silencer and documents.
Cologne, GermanyInjection pump MAN D2842
- Manufacturer: MAN
- Model: D2842
Injection pump MAN D2842 used machine Bosch Injection Pump for MAN D2842 LE211 with GAC controller, cf. MAN part number: 51.11103-7451 59.11103-7451 N (l/min): 750 RW (mm): 12.7 or H5149616 13.6
Hamburg, Germany- Trusted Seller
MAN emergency generator D2842 LE20 - 548 KVA
- Manufacturer: MAN
- Model: D2842
- Hours: 1.438
- Power: 548
MAN emergency generator D2842 LE20 Diesel emergency generator from 1991 with 1,436 operating hours, engine and AC generator on base frame, control, circuit breaker and cooling (water). 1 available 438 KWel x 1,50...