FU2200A Digital ethernet power meter with data logger in Beijing, China
New
Doubleclick to zoom in
Contact the seller for
additional photos and information.
Specifications
- Condition
- new
- Power supply (ac/dc)
- AC 85-400V/DC 85-330VPower consumption <4VA
- Accuracy class
- 0.5s
- Measurement parameters
- Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF; Phase angle; Active power(W); Reactive power(Q);
- Harmonics
- Total harmonics ratio of phase-voltageTotal harmonics ratio of current2nd to 63rd harmonics ratio of phase-voltage2nd to 63rd harmonics ratio of phase-voltage2nd to 63rd harmonics ratio of current
- Maximum value&minimum value
- Voltage, current, frequency, active power, reactive power, apparent power, demandP, demandQ, demandS.
- Computing
- Forward active power energyReverse active power energyForward active power energyReverse reactive power energy
- Measuring range
- 0-480V (P-N), 0-800V (P-P), 0-10A, 45-65Hz, -1~0~1
- Measuring accuracy
- Voltage 0.5% RD±0.05% FSCurrent 0.5% RD±0.05% FSActive power 0.5% RD±0.05% FSReactive power 1.5% RD+0.05% FSApparent power 0.5% RD+0.1% FSPower factor 0.5% RDFrequency 0.05% RDActive energy 0.5S, 0.5% , 1%
- Maximum demand
- Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
- Data logger interval time
- 1minute-60minutes can be set
- Data logger
- U1, U2, U3, U12, U23, U31, I1, I2, I3, F, P, Q, S, demand, Ep, Eq, Es, Phase, Unbalance, EPrate, EQrate, ESrate
- Load recorder or curve
- Yes
- Display
- Blue back-lit LCD Display5 display figures4 operation keys
- Communication
- Support RS-485 interface port, 32 (128) NetworkingRTU-ModBus-TCP/IP, SNMP communication protocolEthernet 10/100M port (RJ45)
- Memory
- 2M onboard memory, can be extended to 16M.Data looger interval can set by end users from 1min to 60min.The default is 15min.You can read the data through a PC, also you can select the data to diaplay and store from software. You can read the data through a PC , also you can select the data to diaplay and store from software.
- Programmable
- Measuring system 3P4W/3P3W etcTransformation Ratio PT 1-10000; CT 1-10000
- Energy pulse
- Provides active & reactive energy pulse outputPulse parameters can be choosedPulse constant range 0.1-10000kWh/kvarhPulse constant can be programmableDry contact output (1Ax100V) programmableDry contact output (1Ax100V)
- Input every voltage/current compensation
- 0.5VA/channel
- Tariffs
- 4
- Seasons
- 6
- Schedules
- 6
- Connection mode
- 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P3W, 1P2W
- Clock
- Yes
- Baud
- 1200-57600, standard 38400
- Web browser
- Yes
- Pc management software
- Yes, download data to excel file
- Standard
- IEC 62053-21,22,23,24; ANSI C12.20; IEC 62052-11; IEC 62586-2; IEC 61326-1; IEC 61000-4-30 class S; IEEE 519 2014; EN 50160 2010; IEC 61557-12; EN61010- 2-030 2010; EN61326-1 2013; EN61000-3-2 2014; EN61000-3-3 2013; IEC61557-12; IEC60068-2-1/2/30
- Isolation protection
- IEC 61010-1 2001
- Measurement category
- 300V CAT III, 600V CAT II
- Degree of protection
- IP42
- Declaration of conformity
- CE & CNAS certified
- Dimensions (lxwxh)(mm)
- 96x96x14
- Net weight
- 550g
- Mount
- Panel mountingTrepanning 92x92mmThe thickness of installation 84mmDIN mounting (optional)
- Temperature
- -5 to +50°C
- Humidity
- 20% -95% RH, without condensation
- Subcategory
- Machinery
- Subcategory 2
- Power meter
- Listing ID
- 84813216
Description
FU2200A digital ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems.