Specifications
- Condition
- refurbished
- Stock number
- Dionex-07-0780
- Optical system
- Single-beam, reverse-optics design with concave holographic Grating
- Light sources
- Deuterium lamp (30 W) for ultraviolet spectrum analysisTungsten lamp (15 W) for visible spectrum analysis
- Photodiode array
- 1024 elements
- Wavelength range
- 190 nm to 800 nm
- Pixel resolution
- 0.7 nm
- Wavelength accuracy
- ± 1 nm
- Noise
- ± 10 µAU with 2-second rise time, 254 nm, 4 nm bandwidth, and flowing deionized water± 15 µAU with 2-second rise time, 520 nm, 10 nm bandwidth, and flowing deionized water
- Drift
- < 500 µAU/hour (after warm-up)
- Linearity
- > 2 AU
- Analog outputs
- Four built-in analog outputs
- Voltage out
- 1 V output
- Analog output range
- 0.0005, 0.001, 0.01, 0.1, 0.5, 1.0, 2.0, or 3.0 AU full-scale
- Control and data evaluation
- Provided by PeakNet 6 or Chromeleon software; communication with the detector is via the DX-LAN interface
- Cell body
- PEEK or stainless steel
- Volume and optical path length
- PEEK cell: 13 µL volume; 10 mm (0.394 in) path lengthStainless steel cell: 13 µL volume; 10 mm (0.394 in) path length
- Maximum operating pressure
- PEEK cell: 2 MPa (300 psi)Stainless steel cell: 3 MPa (500 psi)
- Chemical compatibility
- -Do not use bases stronger than 0.1 M; they will etch the silica windows of the flow cells.-Do not use normal phase or chlorinated solvents with the PEEK flow cell; they will damage the cell. -Do not use high pH salts with the stainless-steel flow cell; they will cause corrosion, contamination, and metal leaching.
- Category
- Chromatography in Canada
- Subcategory
- Thermofisher hplc
- Subcategory 2
- Thermofisher detectors
- Subcategory 3
- Hplc, uplc & ic products
- Listing ID
- 26190828
Description
The Dionex PDA-100 Photodiode Array Detector is an optical detector capable of measuring the absorbance spectrum from 190 nm to 800 nm. A deuterium lamp optimizes the UV range (190 nm to 380 nm) and a tungsten lamp optimizes the visible range (380 nm to 800 nm).
When using the PDA-100, up to five single wavelengths (2D chromatograms) can be collected without being required to collect 3D data. Collecting individual wavelengths instead of the spectra offers two advantages: it eliminates the need to perform extractions for runs that do not require spectral data and it conserves disk space.
A 90 day warranty is included.
Services offered by seller
This Seller offers repair & maintenance services
This seller offers spare parts
Interested in this machine?
This seller has been contacted 11 times in the last week.