Roche Cobas 6000 (c501 + e601) Chemistry Analyzer in Temecula, CA, USA

Specifications

Condition
new
System
2nd Generation SWA: modular, analytical system platform, consolidated work area for Clinical Chemistry and Immunology, expandable and re-configurable on site
Types of modules
· cobas c 501 module: Photometric measuring unit (incl. ISE) · cobas e 601 module: Electrochemiluminescence (ECL) technology measuring unit
Number of configurations
7 module combinations; Up to 3 modules in one core unit · cobas c 501 modules: 1 to 2 modules · cobas e 601 modules: 1 to 2 modules · cobas c 501 | cobas e 601 modules: 2 to 3 modules (only 2 units of 1 module type for SWA combinations possbile)
Sample throughput
Up to 120 racks/hour or 600 samples/hour
Test throughput  (theoretical max)
· 170 up to 2,170 tests/hour: overall · 1,000 up to 2,000 tests/hour:with cobas c 501 modules · 170 up to 340 tests/hour:with cobas e 601 modules · 1,170 up to 2,170 tests/hour: with cobas c 501 and cobas e 601 modules
Number of reagent channels  (reagent slots)
Up to 151 channels, in total 63 channels (including ISE, automatic setting) on cobas c 501 module 25 channels on cobas e 601 module
Sample material
Serum, Plasma, Urine, CSF
Core unit analytics
· Rack: 5 position rack, RD standard rack · Rack types: Routine, STAT, Control, Calibrator, Rerun (manual), Wash · Tray: Tray with 15 racks/75 samples, RD standard tray · STAT port: STAT samples are processed with true STAT interrupt
Sample container types
· Primary tubes: 5 to 10 mL; 16 x 100, 16 x 75, 13 x 100, 13 x 75 mm · Sample cup: 2.5 mL · Micro cup: 1.5 mL, (exception: cobas e 601 module) · Cups on tube: Cup on top of a 16 x 75/100 mm tube; Cup on top of one non standard tube · False bottom tube (FBT): One type is definable
Sample volume
1–35 µL
Sample dilution
3–121 times
Sample clot detection
Available for cobas c 501 and cobas e 601 module
Minimum sample volume
· Primary tubes: 700 µL · Sample cup: 100 µL · Micro cup (FTB): 50 µL
Sample barcode types
Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39
System interfaces
RS 232 serial interface, bi-directional Interface to cobas link data station for cobas teleservice functionalities and automatic download
Sample data base
10.000 routine/STAT samples
Test methods
For photometric modules: 1 point, 1 point + prozone check, 2 point, 2 point kinetic, 2 point + prozone check, 3 point, 1 point + kinetics Rate A, Rate A + serum index, Rate A with blank, Rate B
Calibrator/qc input
Via specified racks through the input buffer or STAT port
Calibration methods
Start-up, Re-calibration For photometric modules: Linear, non-linear multi-points, 2 point calibration, K-factor up to 100 different calibrators pre-programmable Storage of up to 180 curves Preventive calibration of the stand-by cobas c and cobas e packs on cobas c 501: Two k-factor can be defined for different sample types
Qc methods
For e- and photometric modules: Real-time QC, individual QC, cumulative QC Up to 100 controls pre-programmable Preventive QC after calibration of the stand-by cassettes/rack packs Auto QC: QC without operator intervention (timer triggered)
Rerun/reflex function
Automatic rerun and manual rerun; Automatic reflex is supported by the system, reflex request to be provided by Roche Middleware Solutions
Electrical requirements
· Power requirements: 230 Volts AC; 110 Volts AC 2.4 kVA (for cobas c 501 | e 601) · Frequency: 50 Hz or 60 Hz +/- 0.5%
Water/waste requirements
· Water: Bacteria free, deionised water supply: resistance of < 1,0 µS/cm · Water pressure: 0.5 – 3.5 kg/cm3, (49–343 Kpa) · Biohazards waste: Separate container behind the system · L. concentrated: Central drain port, diameter: = 50 mm / 2 inches · Waste drain < waste: 100 mm above the floor / 4 inches
Water consumption
· Max flow rate: cobas c 501 module: approx. 40 L/hour · Typical consumption: cobas e 601 module: approx. 30 L/hour
Operational conditions
· Ambient temperature: 15 to 32°C / 59 to 90°F · Ambient humidity: 30 to 85% (RH, without condensation) · Heat output: 1.5 kW (5400 kJ/hr for cobas c 501, 4320 kJ/hr for cobas e 601) · Noise output: < 65 dB
Physical dimensions
· Width: 188 to 498 cm / 74 to 196 inches · Core unit: 69 cm / 27.2 inches cobas c or cobas e module: 120 cm / 47.2 inches · Depth: cobas c or cobas e module: 98 cm / 38.6 inches Core unit: 104 cm / 41 inches · Height: 130 cm / 51 inches · Control unit: Width: 80 cm / 31.5 inches, depth: 80 cm / 31.5 inches
Weight
· cobas c 501 module: 330 kg / 730 lbs · cobas e 601 module: 360 kg / 795 lbs · Core unit (sample loader, control unit, rack rotor): 180 kg / 400 lbs
Subcategory
Clinical equipment
Subcategory 2
Chemistry analyzers
Listing ID
105287615

Description

Roche Cobas 6000 (C501 + E601) Chemistry Analyzer for sale

The Cobas 6000 analyzer series offer tailor-made solutions to medium to large workload laboratories. Flexible combinations of clinical chemistry (cobas c 501 module) and immunochemistry testing (cobas e 601 module) modules are available.

CORE UNIT :

- Simple operation with continuous loading and unloading

- Loading capacity of 150 samples in two trays of 75

- Load 5-position racks via dedicated STAT port with rerun buffer or by tray

- Unique 5-position rack for more efficient sample handling

- Smart track rotor for intelligent sample handling

Single control unit for all modules

COBAS C501 MODULE

Clinical chemistry, homogeneous immunoassays, ISE, HbA1c (whole blood measurement).

- Throughput of up to 1,000 tests/hour

- 60 reagent channels plus 3 ISE’s

- Reagent loading on the fly

- Specimen integrity via serum indices (parallel processing), clot and liquid level detection

- Contact-free ultrasonic mixing

Automated rerun and dilution

COBAS E601 MODULE

Heterogeneous immunoassays including cardiac markers, anemia, bone and tumor markers, hormones, and infectious diseases.

- Electrochemiluminscence (ECL) technology

- Throughput up to 170 tests/hour

- 25 reagent channels

- Carry-over free disposable tips and cups

- 9-minute STAT applications for Troponin I and T, proBNP II, Myoglobin, hCG and CKMB

- Clot and liquid level detection

Automated rerun and dilution

Escape from corporate service contracts in California

The quality of service contracts from manufacturers has declined over the last 10 years.

They’re less responsive. Slower. More corporatized. You submit service tickets or contact your service tech through a central email inbox.

Most lab managers aren’t interested in all that hooplah. You want an easy transaction to get your system up and running again.

Your service agreement with us is more like this:
- Your service engineer is local in California.

- Call or text your service engineer directly.

- Get same day phone service, next day on-site service in California, and next-flight on-site service anywhere in the US.

- You get faster repairs because we keep parts in stock manufacturers don’t. In fact, there’s a good chance your manufacturer comes to us for replacement parts (and marks up the price).

Increase throughput, uptime, and the value of every test

Your refurbished Roche Cobas 6000 or other Roche Cobas system is returned to like-new specs – like the day it rolled off the Hitachi production line.

But it’s tens of thousands of dollars less than the day it rolled off that production line.

The capacity it adds to your lab means the investment pays for itself within 2 years.

And the responsive service you get from us means your uptime is better than your other analyzers (unless you lump all your service together with us – then your entire lab’s uptime will increase by weeks annually).

Even large labs have to manage expenses carefully. They have to be profitable.

You can get financing terms quickly with us. Then the increase in efficiency, reduced overall testing downtime, and increased test throughput (coupled with the low purchase price of a refurbished Roche Cobas) account for most of your payments.

The improvements in your lab pay for themselves.

Finance your Roche Cobas & let it pay for itself
Manage your capital equipment budget easily

Your refurbished Roche Cobas is returned to OEM-or-better condition (because over the last 15 years, replacement parts have improved in quality).

You reduce the wear and tear on your primary analyzers. You reduce the cost of repairs.

You may extend the lifespan of your more expensive chemistry analyzers by 5+ years.

Click here & make your job easier

Make onboarding new staff easier in California

Hiring new staff in your lab is challenging.

Labs managers are bending over backwards to retain their experienced staff.

They’re the most valuable asset in any lab because experienced operators can step into any scenario and adapt quickly. They can handle the steep learning curves of new equipment and processes.

The pool of experienced operators who are going to move from their job to a new role in your lab is small.
You usually have a large pool of less experienced lab technicians to choose from, and the time you put into that inexperienced candidate is risky.
- They might not be able to get a handle on the complexity of your systems.

- Training is expensive. It costs you and your experienced operators time. It costs money in errors and waste.

- After all your training, they may move on to a higher paying job. Leaving you to do it all again.

Hiring and onboarding new staff costs you close to $20,000.

Equipping your lab with a refurbished Roche Cobas makes most of that hassle obsolete.

Because it’s been in circulation for more than 15 years, there’s a good chance that most inexperienced candidates have still used it. They’re likely even proficient using it.

Your training time is drastically reduced.

Their rate of errors is drastically reduced.

The oversight you have to give them in the first 9 months is drastically reduced.

It’s a bit like a babysitter for baby lab techs. But you don’t have to buy it pizza.
Click here for a quick quote
Get personal, responsive service in California that values your time
“Roche doesn’t have the service techs in my region any more to support our Cobas 6000 workhorse. So we almost had to retire the system that churns out our most common tests. But we found IDE and started working with a service engineer who lives 10 minutes away. We have more uptime now and we’re considering adding a refurbished system to help cope with the growing expectations to generate results faster than ever.”

So. Cal. Medical Center

How many times have you had to convince your service provider you need them

How often have they patronized you? Frustrated you? Treated you like you’re doing something wrong?

When you call or text your service engineer at IDE directly, you get help from a friend. We’re a family business, and you’re part of the family.

It’s not your job to know how to fix obscure problems with your chemistry analyzer. You serve patients. You’re responsible for a huge volume of data.

You never have to attempt a repair on your own. We’ll walk you through exactly what you need to do and we’ll stay on the line until you’re up and running.

That’s the work and the worry we take off your shoulders.

Learn more about your local service in California
Get everything you need for your Roche Cobas or other analyzer in one place

You shouldn’t have to cobble together parts and services from multiple suppliers to support your work.

With IDE, you get a curated collection of everything you need to run your Roche Cobas or other chemistry or immunochemistry system in one place.

Find everything you need below, or contact us and tell us what’s going wrong.

Don’t wait for a large service provider from out-of-state to triage your problem. Get it fixed now.

Trade in your instrument to save on your next refurbished system!

Your lab may be shifting priorities.

Trade in the system you don’t want anymore and put the value toward an upgrade.

There’s always another lab that could use your old analyzer. We’ll rebuild it from the frame and ensure it continues to provide value to your colleagues somewhere else.

It’s a great way to maintain your lab’s low environmental impact and stop old materials from ending up in a landfill.

Plus, it will have a huge impact on the price of your upgrade.

Contact us to trade in your old instrument and save
Service for your Roche Cobas in California
Get everything, from parts to reagents to preventative maintenance and other service, in one place. Build a relationship and get the personal attention your lab wants. Don’t get treated like a number.

Preventative maintenance
Get ahead of impending errors and limit downtime.

Tailored service agreements
Don’t sign on for a one-size-fits-all solution. Choose a bespoke service agreement for your unique challenges.

Same day phone support
You don’t always need to wait for someone to come to you. Sometimes you just need to talk through your problem. Get that help today.

Affordable depot service
It costs money to send an engineer to your site. Instead, send your instruments to us for repairs, service, or refurbishment.

Decontamination and relocation
This isn’t like moving a couch. Get qualified help to move your valuable instruments.

Installation, training, validation
Get installation, IQ/OQ validation, onsite structural review, power connection, alignment validation, calibration and quality control. Plus, get professional training for lab technicians to safely and correctly use instruments and perform tests and basic maintenance (reducing your long term costs).
We’re eager to help out. Contact us here today

Test Menu

COBAS c 501 Module

6AM
BILT3
FEN2
LPA2
SVTCH

A1C-3
BUP
FERR4
LSD
SVTCR

A1MG2
C3C-2
FRA
MDN2
SVTNI

A2MG
C4-2
GENTC
Methadone Metabolite
SVTOX

AAGP2
CA2
GGT-2
MG2
SVTpH

AAT2
CARB4
GLUC2
MPA
SVTSG

ACET2
CERU
GLUC3
MTQL
THC2

ALB2
CHE
HAPT2
MYO2
THEO2

ALBP
CHE2
HCYS
NAPA2
TOBR2

ALP2
CHOL2
HDLC4
NH3L
TP2

ALT
CK
HYD
NH3L2
TPUC3

ALTL
CO2-L
IGA-2
OPI2
TRIGL

ALTLP
COC2
IGG-2
OXY
TRSF2

AMIK 2
CREJ2
IGM-2
PCP
UA2

AMPS2
CREP2
IRON2
PHNO2
UIBC

AMY-P
CRP4
ISE Chloride Electrode
PHNY2
UREAL

AMYL2
CRPHS
ISE Potassium Electrode
PHOS2
VALP2

APOAT
CRPLX
ISE Sodium Electrode
PPX
VANC3

APOBT
CYSC2
KFLC
PREA
β2-Microglobulin

ASLOT
D Bili
LACT2
PROC2

ASTL
D-DI
LDHI2
QUIN2

ASTLP
DIG
LDLC3
RF-II

B2MG
EDDP
LFLC
SALI

BARB
ETOH2
LI
SI2

BENZ
FCAL
LIPC
STFR

COBAS e 601 Module

Elecsys ACTH
Elecsys Cyclosporine
Elecsys Insulin
Elecsys Total-Tau CSF

Elecsys AFP
Elecsys CYFRA 21-1
Elecsys LH
Elecsys Toxo IgG

Elecsys AMH
Elecsys DHEA-S
Elecsys Myoglobin
Elecsys Toxo IgM

Elecsys Anti-CCP
Elecsys Digoxin
Elecsys N-MID Osteocalcin
Elecsys Troponin I

Elecsys Anti-HAV
Elecsys Estradiol III
Elecsys NSE
Elecsys TSH

Elecsys Anti-HAV IgM
Elecsys Ferritin
Elecsys PAPP-A
Elecsys Vitamin B12 II

Elecsys Anti-HBc IgM
Elecsys Folate III
Elecsys Phospho-Tau (181P) CSF
Elecsys β -CrossLaps/serum

Elecsys Anti-HBc II
Elecsys Folate RBC
Elecsys PlGF

Elecsys Anti-HBe
Elecsys free PSA
Elecsys proBNP II

Elecsys Anti-HCV II
Elecsys free βhCG
Elecsys Progesterone III

Elecsys Anti-SARS-CoV-2 S
Elecsys FSH
Elecsys ProGRP

Elecsys Anti-Tg
Elecsys FT3 III
Elecsys Prolactin II

Elecsys Anti-TPO
Elecsys HBeAg
Elecsys PTH

Elecsys Anti-TSHR
Elecsys HBsAg Confirmatory Test
Elecsys Rubella IgG

Elecsys BRAHMS PCT
Elecsys HBsAg II
Elecsys Rubella IgM

Elecsys C-Peptide
Elecsys HCG STAT
Elecsys S100

Elecsys CA 125 II
Elecsys HCG+β
Elecsys SARS-CoV-2 Antigen

Elecsys CA 15-3 II
Elecsys HE4
Elecsys sFlt-1

Elecsys CA 19-9
Elecsys hGH
Elecsys SHBG

Elecsys Calcitonin
Elecsys HSV-1 IgG
Elecsys Syphilis

Elecsys CEA
Elecsys HSV-2 IgG
Elecsys T-Uptake

Elecsys CK-MB
Elecsys IgE II
Elecsys T3

Elecsys CMV IgG
Elecsys IGF-1
Elecsys T4

Elecsys CMV IgM
Elecsys IGFBP-3
Elecsys Tacrolimus

Elecsys Cortisol II
Elecsys IL-6
Elecsys Testosterone II

Elecsys total PSA

COBAS 6000 TECHINCAL SPECIFICATION

Contact Seller for Price

Manufacturer
Roche
Type
Biochemistry Analyzers
Location
🇺🇸 Temecula, CA, USA

Interested in this machine?

This seller has been contacted 7 times in the last week.

Trusted Seller

4.25
Get Financing

Our financing partner can help you get fast, easy, and affordable financing for your equipment purchase