Dynex DS2 Automated ELISA Processing System in Temecula, CA, USA

Specifications

Condition
new
Width
54 cm            21 in
Depth
68 cm             27 in
Height
66 cm             26 in
Footprint
0.36 sq m         3.9 sq ft
Bench weight
48 kg            105 Ib
Ship weight
78 kg             170lb
Noise
Noise output     < 78 dB
Number of plates
2
Sample capacity
100 per load
Continuous sample loading
Yes
Sample tube size
10 mm – 16 mm diameter
Number of reagents
Up to 8 (25 mL tubes)
Standard/control bottles
24 (2 mL vials)
Assays per plate
Up to 12
Dilution wells capacity
Up to 96 deep-well strips (12 x 8)
Sample tip capacity
216 tips (2 x 108)
Reagent tip capacity
20 tips
Photometric range
0.100 – 3.0 OD
Spectral range
405 nm – 690 nm
Filter slots
6 wavelength
Precision
< 1% CV (< 2.0 OD)
Accuracy
± 0.005 OD or 2.5
Read time
< 30 sec (single wavelength)
Manifold configuration
8-way
Programmable volumes
50 µL – 1,000 µL
Wash buffer capacity
2 wash bottles at 2 L, with level-sensing
Residual wash volume
< 3 µL with super sweep
Dispense precision
≤ 5% CV (with 300 μL in a 96 well plate)
Waste container
1 x 1.5 L
Number of incubators
2
Temperature range
Ambient + 4° C to 40° C
Temperature accuracy
± 1° C across plate @ 37° C
Shaking
Independent linear motion
Temperature monitoring
Yes
Reagent tip size
1,300 µL
Reagent pipetting volume
20 μL – 1,000 μL
Precision, reagent tip
< 3% CV at any operating volume above
Sample tip size
300 μL
Sample pipetting volume
10 μL – 250 μL
Sample pipetting precision
< 3% CV at any operating volume above
Dilution range
1 part in 199 one-stage dilution
Liquid level sensing
Yes (reagents, controls and samples)
Level sensor system
Pressure di erential
Clot detection
Yes
Dispense anomaly detection
Yes
Tip detection
Yes
Electronic signature pipetting
Yes
Alarms
Yes
Controlling software
DS-Matrix
Work protocols (assays)
Unlimited
Data processing
Quantitative and qualitative
Levey-jennings
Yes
Westgard rules
Yes
Process reporting
Event log + error log
Automatic error recovery
Yes
Password access control
Yes
Subcategory
Clinical equipment
Listing ID
105287543

Description

Dynex DS2 Automated ELISA Processing System

Run any assay from any vendor

- Fully automated open system

- Ability to bring in tests that are currently being sent out

- Automated sample distribution, incubation, reagent addition, washing and detection steps of assays as defined by the manufacturer. The lab can customize assay parameters, assay steps, OD read settings, result calculations, quality control checks and report formats with ease

Reliable workload scheduling

- For the past 2 years DYNEX DS2 has achieved 98.5 uptime when mean time between failure target is set at 250 days

- Schedule your preventive maintenance during slow period

- Electronic Signature Pipetting (ESP) is a sophisticated technique used by the DS2 for detection of gross pipetting errors often caused by the presence of particulate matter, clots, foam, or bubbles in the sample. Insufficient sample transfer can therefore be detected and reported to the operator during a run

- Prevent unscheduled down time

Saves Space

- The DS2 system footprint is less than four square feet of linear counter space to process up to two 96-well microplates and 100 specimens making it ideal for lab’s expanding workload

- Utilize the same linear space as manual incubator and reader

The innovative DS2 is designed for clinical, research and industrial labs that want to enhance their processes through automation. Installed in over 3,500 labs worldwide, the DS2 is the solution for the rigorous, repeatable analyses required in critical applications including immunology, infectious disease, hormone, allergy, blood-chemistry, drugs-of-abuse testing, food safety, forensics, and environmental testing among others.

Physical Specifications
Dimensions Metric Non Metric
System Specifications
40 mm – 100 mm height
Up to 10 (15 mL tubes)
Number of
Reader Specifications
< 2% CV (2.0 – 3.0 OD)
(0.000 – 3.000 OD) whichever is greater
Washer Specification
Incubator Specifications
14 – 20 Hz (periodic or continuous)
Reagent Pipetting Specifications
20 uL (single-shot mode)
Sample Pipetting Specifications
10 uL (single-shot mode)
1 part in 39,601 two-stage dilution
Process Security
Software

Contact Seller for Price

Manufacturer
Dynex
Type
Immunoassay Analyzers
Location
🇺🇸 Temecula, CA, USA

Interested in this machine?

This seller has been contacted 7 times in the last week.

Trusted Seller

4.25
Get Financing

Our financing partner can help you get fast, easy, and affordable financing for your equipment purchase