Thermo Scientific SureSTART Electronic hand held battery operated crimper: suitable for 11mm crimp caps. Generation 4 ; Level 3 High Performance Applications
- Manufacturer: Thermo Fisher Scientific
The SureSTART Performance Levels: Level 1: Everyday analysis Chromatography approved SureSTART Level 1 products are cost optimized, suitable for all instrument types, and quality tested to deliver the performance...
Nottingham, United KingdomChromolith CapRod RP-18e 150-0.05
Analysis Note Pressure: 5 - 25 barTheoretical Plates (N/m) (hexylbenzene): ≥ 80000capacity factor, k′ (hexylbenzene): 0.80 - 1.80Tailing (USP): 0.90 - 1.30 %Selectivity, A (Hexylbenzene/Pentylbenzene): 1.40 - 1.6...
Nottingham, United KingdomZIC-PHILIC?(5UM) PEEK 150X4.6
Analysis Note Theoretical Plates (N/m) (Cytosine): ≥ 40000Symmetry (Cytosine): 0.95 - 1.40 General description SeQuant® ZIC®-pHILIC stationary phase has the same highly polar, bonded, permanent zwitterion, functi...
Nottingham, United KingdomThermo Scientific SureSTART Electronic hand held battery operated crimper: suitable for 20mm crimp caps. Generation 4 ; Level 3 High Performance Applications
- Manufacturer: Thermo Fisher Scientific
The SureSTART Performance Levels: Level 1: Everyday analysis Chromatography approved SureSTART Level 1 products are cost optimized, suitable for all instrument types, and quality tested to deliver the performance...
Nottingham, United KingdomThermo Scientific SureSTART Electronic hand held battery operated crimper: suitable for 13mm crimp caps. Generation 4 ; Level 3 High Performance Applications
- Manufacturer: Thermo Fisher Scientific
The SureSTART Performance Levels: Level 1: Everyday analysis Chromatography approved SureSTART Level 1 products are cost optimized, suitable for all instrument types, and quality tested to deliver the performance...
Nottingham, United KingdomThermogreen LB-2 Septa, solid discs, diam. 10.0 mm ( 13/32), pkg of 1000 ea
Application Thermogreen® LB-2 Septa is suitable for the following applications: • To minimize extraction onto or loss of analytes off the solid phase microextraction (SPME) fiber from the vial during analysis by ...
Nottingham, United Kingdomdomnick hunter NITROX UHP Hydrogen Generator, Model 20H, output flow, 0 - 160 cc/min
- Manufacturer: Domnick Hunter
General description domnick hunter hydrogen generators are a safe and economic alternative to high pressure gas cylinders. These generators deliver a continuous stream of 99.999% pure hydrogen, suitable for use w...
Nottingham, United Kingdomdomnick hunter NITROX UHP Hydrogen Generator, Model 40H, output flow, 0 - 250 cc/min
- Manufacturer: Domnick Hunter
General description domnick hunter hydrogen generators are a safe and economic alternative to high pressure gas cylinders. These generators deliver a continuous stream of 99.999% pure hydrogen, suitable for use w...
Nottingham, United Kingdom