Electrochemical Detector
The electrochemical detector requires the occurrence of electrolytic reaction in the electrolytic cell, that is, under the action of applied voltage, it is a method to measure the change of current caused by the ...
Shandong, China
Column Maintenance System
The SH-CM column maintenance system focuses on the maintenance of LC and IC column, releasing the inspection and detection capability of equipment such as LC / LCMS / IC, while maximizing the protection of equipm...
Shandong, China
Electromagnetic Ten-way Injection Valve
SH series injection valve is an electromagnetic injection valve independently developed by SHINE. It uses a stepping motor to control the valve position switch. It has good sealing performance, compact structure,...
Shandong, China
Oxygen Bomb Combustion Sample Processing Device
The oxygen bomb combustion sample processing device is a pretreatment device for analyzing solid and liquid organic samples. The samples are burned in a airtight pure oxygen system.The components to be measured a...
Shandong, China
Post-column Derivatization System
Connected with HPLC and equipped with derivative reagent, it can detect glyphosate, aminomethylphosphonic acid, paraquat, amino acids, biological polyamines, streptomycin, carbamate insecticides, amino sugar anti...
Shandong, China
Vacuum Degasser
The bubbles are formed by dissolving or mixing air in the mobile phase solution, and noise peaks appear on the chromatogram when the bubbles enter the detector. When the bubbles enter the flow path or column, the...
Shandong, China
Conductivity Cell
The conductance detector continuously detects the conductivity of the eluate by loading voltage on the two electrodes in solution. The patented design of constant temperature conductivity detector can reduce the ...
Shandong, China
SH-AC-17 Anion Column
A special anion column for I- with conductivity method, using hydroxide system is mainly applicable to the analysis of I-, SCN- and S2O32- in the environment, solid waste and other industries. IC Columns are comp...
Shandong, China
SH-AC-14 Anion Column(PEEK)
An special anion columns with PEEK tube .It is usually equipped with DC ampere detectors to detect S2- and CN-. IC Columns are compatible with Dionex, Metrohm, Shimadzu systems
Shandong, China
SH-AC-19 Anion Column
A microbore anion column, using hydroxide system eluent . With fine particle diameter, low flow rate and high signal response value,it can simultaneously analyze 8 kinds of anions:F-,BrO3-,Cl-,NO2-,Br-,NO3-,PO43-...
Shandong, China
SH-AC-3 Anion Column
An anion column with high efficiency, using carbonate system can simultaneously analyze 7 kinds of common anions (F-, Cl-, Br-, NO2-, NO3-, H2PO4-, SO42-), disinfection by-products (BrO3- ,ClO2- ,ClO3- ,dichloroa...
Shandong, China
SH-AC-20 Anion Column
A microbore anion column, using carbonate system eluent With fine particle diameter, low flow rate and high signal response value,it can simultaneously analyze 8 kinds of anions :F-,BrO3-,Cl-,NO2-,Br-,NO3-,H2PO4-...
Shandong, China
Neutralization Device
The neutralization device is an online sample pre-processing device, which is mainly used for the detection of anions and cations in strong acid and alkali samples. Using electrodialysis and membrane exchange tec...
Shandong, China
Electromagnetic Six-way Injection Valve
SH series injection valve is an electromagnetic injection valve independently developed by SHINE. It uses a stepping motor to control the valve position switch. It has good sealing performance, compact structure,...
Shandong, China
Manual Six-way Injection Valve
SHMV-P6-1 manual six-way injection valve is a universal injection valve, which is widely used in IC and LC. Cutting valve continuous flow design is adopted to avoid the impact of instantaneous pressure on the sys...
Shandong, China