Building Filters
EXCHANGERS 112852
Used 3007 sq. ft. U-Tube exchanger. Mfg. by Energy Exchanger Company. Previous Service: Makeup Water Trim Heater.
Cleveland, TXEXCHANGERS 102479
- Manufacturer: CO A S T
MFG. BY CO. A.S.T. IN 1992; 253.8 SQM 316L SS TUBE HEAD; CS SHELL VERTICAL HEAT EXCHANGER (RE-BOILER); 9000MM LENGTH; 2300MM WIDTH; 2000MM HEIGHT; DESIGN PRESSURE TUBE SIDE 22 BAR @ 300 DEG. C.; SHELL 8 BAR @ 2...
Cleveland, TXEXCHANGERS 114544
Used 603 sq. ft. vertical exchanger. Mfg. by Perry Products in 2012. 16" diameter x 16'0" F/F. Shell, tubes and heads 304 stainless steel. 75FV @ 300 deg. F. shell. 75FV @ 300 deg. F. tubes. (192) 3/4" O.D. x 18 GA.
Cleveland, TXEXCHANGERS 114546
Used 75 sq. ft. vertical exchanger. Mfg. by Yula in 2018. 6" diameter x 8'0" F/F. Shell is 304L stainless steel, tubes and heads are 316L stainless steel. 150FV @ 400 deg. F. shell. 150FV @ 400 deg. F. tubes. (...
Cleveland, TXEXCHANGERS 114445
Used 200 sq. ft. recovery still horizontal exchanger. Mfg. by Perry Products in 1991. 8'0" F/F. (153)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV psi @ 300 de...
Cleveland, TXEXCHANGERS 114439
Used 120 sq. ft. horizontal exchanger. Mfg. by Perry Products. 10" diameter x 8'0" F/F. (121)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV psi @ 300 deg. F. He...
Cleveland, TXEXCHANGERS 114442
Used 162 sq. ft. dryer horizontal exchanger. Mfg. by Perry Products. 12" diameter x 6'0" F/F. (165)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV psi @ 300 deg....
Cleveland, TXEXCHANGERS 114440
Used 118 sq. ft. concentration vessel horizontal exchanger. Mfg. by Perry Products. 10" diameter x 8'0" F/F. (121)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV...
Cleveland, TXEXCHANGERS 114437
Used 166 sq. ft. ring closure reactor horizontal exchanger. Mfg. by Perry Products. 12" diameter x 8'0" F/F. (127)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV...
Cleveland, TX- Cleveland, TX
EXCHANGERS 100430
- Manufacturer: HEATRAN
CONVERTER FEED EFFLUENT EXCHANGER (1000 T/D NH3 PLANT); MFG. BY HEATRAN;
Cleveland, TXEXCHANGERS 93470
- Manufacturer: DOYLE & ROTH
EXTERNAL EXCHANGER AUX RX COOLER; MFG. BY DOYLE & ROTH IN 1990; SB626-B2 TUBES;
Cleveland, TXEXCHANGERS 98868
- Manufacturer: EFCO
KELLOGG #123-C; NH3 CONVERTER EFFLUENT/BFW EXCHANGER; MFG. BY EFCO IN 1999; SPECIAL ALL WELDED;
Cleveland, TX- Cleveland, TX
EXCHANGER
Shell pressure (psi): 150 | Tube pressure (psi): 150 | Shell temperature (deg f): 100 | Tube temperature (deg f): 150 | Shell passes: 1 | Tube passes: 1 | Length (ft): 12 | Orientation: H | Shell material: CS | ...
Houston, TX