GS+7H2S Tecnosens
new
- Manufacturer: Tecnosens
Typical Baseline Range: <±1 ppm H2S equivalent Measurement Range: 0 - 200 ppm Output Signal: 370 ± 100 nA / ppm Linearity: Linear Repeatability: < ±1% H2S equivalent Response Time, T90: <40 s Maximum Overload: 10...
Brescia, ItalyGS+7CL2 Tecnosens
new
- Manufacturer: Tecnosens
Measurement Range 0 - 20 ppm Output Signal 1000 ± 300 nA / ppm Linearity: Linear Repeatability < ±2% Cl2 equivalent Response time, T90 <60 s Maximum Overload 250 ppm Long-term Output Drift <20% per annum Recommen...
Brescia, ItalyGS+4NH3-300 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 300 ppm Typical Baseline Range (pure air) ±2 ppm NH3 equivalent Output Signal 40 ± 15 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 500 ppm Long-term Output Drift <20% per annum Reco...
Brescia, Italy3NT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-100 ppm Sensitivity Range: 0.55 ± 0.11 μA/ppm Baseline Offset at 20°C: 0 to 3 ppm equivalent Bias Potential: +300 mV Linearity: linear Response Time at 20°C: < 10 seconds (t90) Long Term Sensit...
Brescia, Italy3HYT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-1000ppm Sensitivity Range: 30 ± 10 nA/ppm Baseline Offset at 20°C: 0 to 15 ppm equivalent Bias Potential: Not required Linearity: Linear Response Time at 20°C: < 50 seconds (t90) Long Term Sens...
Brescia, ItalyFCX-MW-F Tecnosens
new
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-95% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, ItalyFCX-MEP2-F Tecnosens
new
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-25% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, ItalyGS+4NH3-100 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 100 ppm Typical Baseline Range (pure air) ±1 ppm NH3 equivalent Output Signal 100 ± 30 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 200 ppm Long-term Output Drift <20% per annum Rec...
Brescia, ItalyGS+4ETO Tecnosens
new
- Manufacturer: Tecnosens
Measurement Range 0 - 20 ppm Output Signal 1900 ± 600 nA / ppm Linearity: Linear Repeatability < ±2% ETO equivalent Response time, T90 <120 s Maximum Overload 100 ppm Long-term Output Drift <20% per annum Recomme...
Brescia, ItalyGS+4CO Tecnosens
new
- Manufacturer: Tecnosens
Electrochemical carbon monoxide cell with range 0-2000 ppm, manufactured by DD Scientific Suitable for industrial applications, especially for portable detectors. Range 0 - 2000 ppm Output Signal 70 ± 20nA/ppm Li...
Brescia, Italy2EF Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 2-electrode electrochemical Measurement Range: 0-200 ppm CO Maximum Overload: 500 ppm CO Filter: To remove SO2 and H2S Sensitivity: 0.10 ± 0.02 μA/ppm Resolution: 1 ppm Response T...
Brescia, ItalyAL40DB-002KD-2 Tecnosens
new
- Manufacturer: Tecnosens
Pressure sensor composed of silicon-based piezo-resistive sensing element and a signal conditioning integrated circuit. The signal detected by the sensing element is amplified, temperature compensated, calibrated...
Brescia, ItalyT-300A-3V Tecnosens
new
- Manufacturer: Tecnosens
Miniaturized NDIR module for CO2 measurement. Designed for Indoor air monitoring. Accuracy ± 25ppm ± 5% of reading. Measurement range: 400-5000ppm (400-2000ppm, 400-3000ppm and 400-10000ppm available upon request).
Brescia, ItalyS-300-3V Tecnosens
new
- Manufacturer: Tecnosens
NDIR module for CO2 measurement. Its compact format makes it suitable for a variety of applications from HVAC to greenhouses. The module is in single beam technology so it needs to return to clean air to recalibr...
Brescia, ItalyS-110H Tecnosens
new
- Manufacturer: Tecnosens
S-110H is one of the most compact single beam NDIR modules for CO2 in the world, whose main features are stability and constant compensation to temperature changes. Accuracy ± 50ppm ± 3% of reading. Measuring ran...
Brescia, Italy