COLUMNS 99568
- Manufacturer: Theo Walter Copper Works
MFG. BY THEO WALTER COPPER WORKS; PREVIOUSLY UTILIZED IN VITAMIN C PRODUCTION;
Cleveland, TX
COLUMNS 101304
- Manufacturer: Ryan Industries
MPE BUTANOL SEPARATION COLUMN; MFG. BY RYAN; SHELL AND HEADS 3/16" THICK;
Cleveland, TX
COLUMNS 103277
- Manufacturer: INDUSTRIAL ALLOY
MFG. BY INDUSTRIAL ALLOY IN 1982; SHELL WALL THICKNESS .250"; TOP/BOTTOM HEAD .210";
Cleveland, TX
GEAR REDUCER, 10HP, 168RPM IN, 15RPM OUT, 11:1, CLEVELAND, RT.ANGLE, WORM+PINION [3]
- Manufacturer: Cleveland
GEAR REDUCER, 10HP, 168RPM IN, 15RPM OUT, 11:1, CLEVELAND, RT.ANGLE, WORM & PINION [3]. Mfd.Cleveland, Model 70R, Series 25, 10HP, torque 26400Lbs. Eimco drum filter drive. Chain drive input, 11:1 reduction from ...
Alvin, TX
Cleveland, TX
AIR FIN COOLERS 114683
(1) Fin Fan with two different bundles. With combined 3871 Bare sq. ft. and 81214 Extended sq. ft. Unused; Mfg. by Kelvion Thermal Solutions in 2023. Bundle 18-XF-1502A Product Fractionator Overhead Condenser; 28...
Cleveland, TX
AIR FIN COOLERS 114684
Unued Air Fin Cooler. Product Fractionator Overhead Condenser. Mfg. by Kelvion Thermal Solutions in 2023. Model #1-1030T108. 2857 bare sq. ft. 59,407 extended sq. ft. 30'0" tube length. 23.9 Design duty (MMBTU/hr...
Cleveland, TX
AIR FIN COOLERS 114697
Unused Air Fin Cooler; Lean Amine Cooler. Mfg. by Fabsco in 2024. 2287 bare sq. ft. 48,027 extended sq. ft. 26'0" tube length. 41.1 Design duty (MMBTU/hr). 135FV design pressure @ 300 deg. F. design temperature....
Cleveland, TX
AIR FIN COOLERS 114702
Unused Air Fin Cooler; Flash Steam Condenser. Mfg. by Fabsco in 2023. 1589 bare sq. ft. 33,614 extended sq. ft. 24'0" tube length. 26.64 Design duty (MMBTU/hr). 50FV design pressure barg. @ 350 deg. F, design te...
Cleveland, TX
AIR FIN COOLERS 114700
Unused Air Fin Cooler; Excess MP Steam Condenser. Mfg. by Fabsco in 2023. 2060 bare sq. ft. 43,387 extended sq. ft. 24'0" tube length. 24.36 Design duty (MMBTU/hr). 232FV design pressure barg @ 430 deg. F. design...
Cleveland, TX
AIR FIN COOLERS 114703
Unused Air Fin Cooler; HGU Condensate Air Cooler (for HGU Feed).Mfg. by Kelvion Thermal Solutions in 2023. 1484 bare sq. ft. 31,917 extended sq. ft. 22'0" tube length. 8.24 Design duty (MMBTU/hr). 200FV design p...
Cleveland, TX
Cleveland, TX
SAGEBRUSH 4" CORIOLIS METER SKID 114511
- Manufacturer: SAGEBRUSH
"As is, Where is" Unused Natural Gas 4" x 3" (4") ANSI 600 Coriolis Meter Skid. Mfg. by Sagebrush in 2020. Asme B31.8 design code, design pressure 1350 psig @ (-20) to 120 deg. F.
Cleveland, TX
FREWITT HW6 114102
- Manufacturer: Frewitt
Unused Frewit Modular Hammermill. Model HammerWitt6. Complete with N2 Purging and O2 Control. It is Constructed According to the GMP-Standard required by the WHO. 316L Polished Stainless Steel Product Contact ...
Cleveland, TX
RIETZ RF-18-K 71652
- Manufacturer: RIETZ
SS CONTACT PARTS; 10" DIA. FEED; Qty: 1 | No. of rolls: 0 | Material of chamber: SS | No. of knives: 0 | Hp: 0 | Rpm: 0 | Remarks: REQUIRES DRIVE
Cleveland, TX
Atlas-Copco GA 55 Industrial Compressor
- Manufacturer: Atlas-Copco
- Model: GA 55
Good condition Atlas-Copco GA 55 Industrial Compressors available between 1991 and 2014 years. Located in Sweden and other countries. Click request price for more information.
Sweden